Who might need a UPS in a shared studio?

Administrator who wants a safe shutdown

Your server stays on even when nobody is in the studio. So check both the available battery runtime and whether it can send a shutdown signal to the operating system. Schneider Electric describes how the SMT750IC can shut down safely via a serial or USB connection.

Studio with brief power cuts

You want the server and essential network equipment to stay on during a short outage. The runtime needs to suit their combined load; PowerWalker and CyberPower give runtimes at a specified load for the models mentioned.

User of a quiet shared workspace

If the UPS will be close to workstations, check when its fan runs and how much ventilation space it needs. For the VI 1000 CSW IEC, PowerWalker states that the fan is off in normal mains mode and switches on in battery and AVR modes.

What should you consider when choosing one?

What to consider What should you check? Who is this important for?
Sufficient battery runtime Measure the combined power consumption in watts and compare the runtime at that load with the time you need to bridge an outage or shut down. Check both the W and VA ratings. If I want the server and essential network equipment to keep running together, I need to know how long they will last at their combined load. Around 33% of consumers say battery runtime is their top priority.
Controlled shutdown Check the communication port, operating system support and required software. Test the shutdown procedure before relying on it. When my server is running unattended, I want it to receive an alert and shut down safely. Around 27% of consumers say automatic shutdown is their main consideration.
Suitable for the workspace Check the fan operation for the exact model and allow for the required ventilation space. If the UPS is next to shared workstations, I want to know when its fan may be audible and where the unit can be placed safely. Around 20% of consumers say suitability for the workspace is their top priority.
Connections and power supply Check the input, battery-backed outlets, plugs and output waveform against your equipment. Don’t assume regional variants have the same configuration. When I need to connect the server and network equipment, I want to be sure the plugs and outlets are compatible. Around 20% of consumers put connection compatibility first.

Common buying mistakes

  • Choosing based on the VA rating alone

    The UPS models mentioned have separate VA and W ratings, with runtimes given for a specific load. So the VA rating alone won’t tell you whether the UPS can power your connected equipment for long enough.

    Measure the total power consumption, then compare both the W and VA ratings and the runtime at the measured load.

  • Assuming a battery means the server will shut down safely

    Battery power won’t automatically make the server shut down safely when the battery is nearly empty. Communication, software and the server’s operating system all need to work together.

    Check compatibility with your operating system and test the shutdown sequence using a simulated power cut.

  • Assuming regional variants have the same connections

    The variants mentioned have different IEC and Schuko outlets. CyberPower also says that the contents of the box may differ by region.

    Check the full model code, battery-backed outlets, input plug and supplied cables against your equipment.

UPS brands and models to consider

The features below apply to the specific model codes and variants mentioned. A brand reference alone does not confirm that a model is available in the Netherlands.

Eaton

The Dutch product page describes the 5P Gen2 5P850IG2 as a line-interactive tower UPS with IEC C13 connections.

  • For this model, Eaton lists 850 VA, 680 W, six C13 outlets, a sine wave output, USB communication and a user-replaceable battery. The stated runtime of 13 minutes is at half load.
  • The runtime at half load won’t predict battery life at your server’s and network equipment’s actual load.

CyberPower

The European CP900EPFCLCD is a line-interactive model with Schuko outlets.

  • For this model, CyberPower lists 900 VA, 540 W, six Schuko outlets and a pure sine wave. The stated runtime of seven minutes is at half load.
  • CyberPower warns that the contents of the box may vary by region, so check the variant and the parts supplied.

PowerWalker

The VI 1000 CSW IEC is a line-interactive model with IEC outlets; the VFI 1000 AT is an online double-conversion UPS.

  • PowerWalker says the USB connection on the VI 1000 CSW IEC is HID-compatible. The manufacturer also states that the fan is off in normal mains mode and switches on in battery and AVR modes.
  • For the VFI 1000 AT, PowerWalker states a 0 ms transfer time from mains to battery in online mode and 10 ms when switching from ECO mode. Check which mode and outlet variant you need.

APC by Schneider Electric

The SMT750IC is a line-interactive Smart-UPS with IEC outlets and communication for a controlled shutdown.

  • For the full model code, Schneider Electric lists 750 VA and 500 W, and describes shutdown via a serial or USB connection.
  • The product page mentioned is for the UK and does not confirm availability or the variant in the Netherlands. Also check the software requirements for your server.

UPS products on Joybuy

Related products coming soon.

Frequently asked questions

How do you work out how much battery runtime your studio needs?

Measure the power consumption of all the equipment that needs to stay on during an outage. Compare the runtime of the exact UPS at that combined load with the time you need to keep working or shut down safely. A runtime at half load won’t necessarily be the runtime you get.

Is a USB connection on the UPS enough for automatic shutdown?

No. The server needs to be able to receive the signal and use the right software or shutdown function correctly. Eaton describes configurable shutdown settings in UPS Companion; check compatibility with your server and test the procedure.

What should you consider when placing a UPS near workstations?

Check the fan operation for the exact model and leave the required ventilation space clear. For the VI 1000 CSW IEC, PowerWalker says the fan is off in normal mains mode and switches on in battery and AVR modes; this won’t necessarily apply to other UPS models.

Which Dutch product safety requirements should you check?

Check the applicable CE marking and electrical safety requirements for the specific variant. According to the Netherlands Food and Consumer Product Safety Authority, the Low Voltage Directive applies to electrical equipment with a rated AC voltage of 50 V to 1000 V. A CE logo does not mean that every individual product has been independently tested.