Who is this relevant to?

Server administrator looking to prevent data loss

Your main aim is to make sure the server shuts down in a controlled way if the power cut lasts longer. Check that the UPS can communicate with your server and that the battery runtime gives it enough time to shut down. Synology Knowledge Center explains how a NAS can use a UPS to save data and safely unmount volumes.

User who needs to keep the server accessible

You want the server to keep running during a power cut. Include any network devices it needs in your calculations for capacity and the runtime you want. Eaton recommends taking both the required capacity and the necessary backup time into account when choosing.

Garden office owner dealing with changing conditions

Check that the location is dry and well ventilated, and that it stays within the temperature range for your chosen model. Eaton and PowerWalker specify temperature ranges for individual models; the Fire Service warns of the risks when batteries come into contact with moisture.

What should you look for when buying?

What to consider What should you check? Who is this important for?
Controlled shutdown Check that your server supports the UPS communication connection and that the runtime under the combined load gives it enough time to shut down. If I want to prevent data loss, the server needs to receive a shutdown signal in time. Around 31% of consumers prioritise controlled shutdown.
Accessibility and backup time Add together the power requirements of your server and the network devices it needs, then compare the total with the W and VA limits and the stated runtime under a similar load. If my server needs to stay accessible, I also want to keep the network equipment powered. Around 25% of consumers put accessibility first.
Positioning in the garden office Compare the conditions at the location with the temperature and humidity limits for the specific model. Also allow for condensation and leave enough space for ventilation. If the temperature in my garden office varies, I want to know first whether the location is suitable for the UPS. Around 25% of consumers prioritise safe positioning.
Connections and battery replacement Check which outlets provide battery backup, whether the plugs fit and what the manufacturer says about replacing the battery. If I want to connect several devices and plan for maintenance, the outlets and replacement battery need to suit my setup. Around 19% of consumers prioritise connections and battery replacement.

Common pitfalls when choosing

  • Assuming the VA rating or maximum wattage guarantees a certain runtime

    Runtime changes with the connected load. Eaton states that the 5E850IUSB provides five minutes at half load; that doesn’t tell you how long the same UPS will last with your server setup.

    Compare the stated runtime under a load similar to that of your connected devices, and allow enough time for a controlled shutdown.

  • Assuming every outlet provides battery power

    According to Schneider Electric, three of the five outlets on the APC Back-UPS Pro BR900G-GR provide battery backup.

    Check which devices will stay powered during a power cut when plugged into each outlet, before connecting your server and network equipment.

  • Placing a UPS somewhere damp or prone to condensation

    Permitted temperature and humidity levels vary by model. The Fire Service points out that moisture can pose a risk to batteries.

    Check the conditions at your chosen location and choose a dry, well-ventilated setup that stays within the model’s specifications.

  • Automatically choosing an online UPS for longer power cuts

    Double conversion and battery runtime address different needs. PowerWalker states that the VFI 1000 AT has an efficiency of 88,0% at full load in mains mode.

    Choose double conversion only if your application needs that type of power supply; assess the runtime you want and ventilation separately.

Brands to compare

Eaton

Eaton offers line-interactive models with USB for communication and controlled shutdown; according to Eaton, the 5SC range is designed for small business servers.

  • According to Eaton, the 5E850IUSB has a capacity of 850 VA and 480 W, four C13 outlets and a runtime of five minutes at half load.
  • The 5SC750I is rated at 750 VA and 525 W in the Dutch product range. These figures don’t automatically confirm compatibility or runtime with your server.

CyberPower

The CP900EPFCLCD is a line-interactive model with Schuko outlets and a pure sine wave output, according to CyberPower.

  • CyberPower specifies 900 VA, 540 W, six Schuko outlets and a runtime of seven minutes at half load.
  • The manufacturer states that it is compatible with active PFC power supplies. Check the requirements of your server’s power supply, as this isn’t an independent test of your setup.

PowerWalker

The VI 1000 CSW is a line-interactive option with a pure sine wave output; the VFI 1000 AT is an online UPS with double conversion.

  • According to the manufacturer, the VI 1000 CSW has a rating of 1000 VA and 600 W, HID USB and a user-replaceable battery. PowerWalker specifies a 0 ms transfer time from mains to battery mode for the VFI 1000 AT.
  • The manufacturer specifies an operating temperature of 0–40 °C for the VI 1000 CSW. For the VFI 1000 AT, the stated efficiency at full load in mains mode is 88,0%; check ventilation and runtime for your load.

APC by Schneider Electric

The Back-UPS Pro BR900G-GR, listed for the Netherlands, is a Schuko model where it’s important to distinguish between battery backup and surge protection only.

  • Schneider Electric specifies 900 VA and 540 W, with five outlets, three of which provide battery backup.
  • The stated runtime of 58 minutes applies to a 100 W load; it doesn’t guarantee the same runtime for a different server setup.

Joybuy products

Related products will be available soon.

Frequently asked questions

How do you work out how much UPS capacity you need?

Start by listing all the devices that need to keep running on battery power. Compare their combined load with both the W and VA limits of the UPS, then check the runtime under a similar load. W and VA aren’t directly interchangeable; the power factor also plays a part.

How do you set up a safe shutdown?

Use a communication connection supported by your server, and configure shutdown so it can finish before the battery runs out. Synology describes a UPS function for its NAS systems that stops services and safely unmounts volumes; for other servers, refer to their own documentation.

Can you keep a UPS in an unheated garden office?

That depends on the conditions you measure and the specific model. Eaton states that the 5E850IUSB has an operating temperature of 0–40 °C; PowerWalker gives the same range for the VI 1000 CSW. These limits don’t automatically apply to other UPS models. Check the humidity requirements too, and prevent condensation.

How should you factor battery replacement into your choice?

Check that a suitable replacement battery is available and find out what replacing it involves for your model. Eaton gives an average lifespan of three to five years for UPS batteries under optimum conditions; this is general information, not a guarantee of how long your battery will last.

How do you dispose of a worn-out UPS or battery in the Netherlands?

Don’t put batteries in your general rubbish. According to the Dutch Government, the collection point depends on the type of battery; other, industrial batteries should be taken to the local authority’s recycling centre. Discarded household electrical appliances can be taken to a local recycling centre or, when a private individual buys a similar new appliance, returned through the old-for-new scheme.