Who is this relevant to?

Home worker who needs to stay online

Wants to get through a short power cut without overlooking an essential part of the connection, such as a separate fibre box. KPN describes the fibre box as a component with its own power connection.

Owner of an unheated garden office

Needs to find a suitable place for the UPS when it could get cold, hot or damp. The permitted conditions vary by model, so check the specifications for the version you’ve chosen.

User with several network devices

Wants to power the modem and other essential equipment at the same time, so compares the number of battery-backed outlets, the combined load and the runtime.

What should you look for when buying?

First, map out which devices your connection depends on and where they’re located. Then decide whether a compatible DC power supply for one device is enough, or whether you want to connect several mains adapters to an AC UPS.

What to consider What to check Who should consider this?
Powering the whole connection Make a list of the modem, any fibre box and other essential devices. Check where their power supplies are plugged in and which outlets provide battery backup. If I need to stay online during a power cut, I don’t want to leave an essential device out of the UPS setup. Around 40% of consumers prioritise powering their entire connection.
Finding a suitable location Compare the temperature and humidity in the intended location with the limits for the exact model, including any conditions relating to condensation. In an unheated garden office, I want to choose a location that suits the conditions my UPS can handle. Around 30% of consumers prioritise finding a suitable location.
Required backup time Check the power consumption of all connected devices and compare the stated runtime only at a relevant load. If I need to stay online for a set amount of time, I want to know how long the complete setup will last. Around 20% of consumers prioritise the backup time they need.
Battery maintenance Check whether the battery is replaceable and which battery type the version you’ve chosen uses. If you want to plan for maintenance after purchase, check in advance whether the battery is replaceable and what conditions apply. Around 10% of consumers prioritise maintenance and ongoing costs.

Common buying mistakes

  • Connecting only the modem to the UPS

    According to KPN, a separate fibre box has its own power connection. If that box is needed during a power cut, a UPS connected to the modem alone won’t keep the whole connection running.

    Map out your connection chain and identify which devices need power and where their power supplies are plugged in.

  • Assuming every outlet provides battery backup

    According to Eaton, three Schuko outlets on the Eaton 3S550DIN have battery backup, while the other three only provide surge protection. A device plugged into an outlet without battery backup won’t keep running from the UPS during a power cut.

    Check the markings on the version you’ve chosen before connecting your devices.

  • Assuming the stated runtime is the modem’s runtime

    CyberPower’s stated 16-minute runtime for the UT650EG is based on a 90 W load. You can’t automatically compare a different load with that runtime.

    Check the power consumption of your connected devices and compare runtime figures at a relevant load.

Brands to consider

APC by Schneider Electric

According to Schneider Electric Netherlands, the APC Back-UPS BE650G2-GR is an AC model with Schuko sockets and a user-replaceable battery.

  • Schneider Electric Netherlands lists the BE650G2-GR as having 650 VA/400 W and eight Schuko sockets.
  • Check which sockets provide battery backup on the exact version, and what runtime to expect at your load.

Eaton

According to Eaton, the 3S550DIN has Schuko outlets with battery backup as well as outlets that provide surge protection only.

  • Eaton lists three battery-backed outlets and a replaceable battery.
  • Eaton marks the 3S550DIN as a model being phased out, so check whether this exact version is available.

CyberPower

According to CyberPower, the UT650EG is a line-interactive AC UPS with automatic voltage regulation (AVR).

  • CyberPower lists three Schuko outlets with battery backup and surge protection for this model.
  • The stated runtime of 16 minutes is based on 90 W; it’s not a runtime measurement for your modem.

PowerWalker / BlueWalker

The DC SecureAdapter 12V provides a DC option for one device with a power supply that’s been confirmed as compatible; the VI 650 SHL is a separate AC UPS range.

  • BlueWalker lists a maximum load of 25 W for the DC SecureAdapter 12V, along with a 5.5 mm outer-diameter and 2.5 mm inner-diameter coaxial connector.
  • The voltage and plug size won’t automatically suit every modem. According to the manufacturer, the VI 650 SHL has two Type F outlets.

Joybuy products

Related products will be available soon.

Frequently asked questions

Should I connect only the modem to the UPS?

Not necessarily. Check which components your connection depends on: KPN, for example, describes a fibre box with its own plug. If that box is needed during a power cut, your backup power setup needs to account for it too.

Can I keep a UPS in an unheated garden office?

Only if conditions in that location stay within the limits for the exact model. Eaton lists an operating temperature of 0–40 °C and a relative humidity of 0–85% without condensation for the 3S550DIN. PowerWalker also lists 0–40 °C for the DC SecureAdapter 12V; check the other environmental limits for that version separately. These are model-specific specifications, not general temperature limits.

How do I know if my modem is plugged into the right outlet?

Check the outlet markings on your model and follow the manual. According to Eaton, three Schuko outlets on the Eaton 3S550DIN have battery backup, while the other three provide surge protection only; those outlets won’t keep a modem running on battery power.

What can I do if a UPS fails too soon during normal use?

According to ACM ConsuWijzer, the retailer is responsible for providing an appropriate solution free of charge if a product doesn’t meet the expectations you’re entitled to have under normal use. This is separate from any manufacturer’s warranty; there isn’t one fixed statutory warranty period that automatically applies to every UPS.

What should I check about electrical compliance?

Check the documentation for the exact version and which rules apply to that equipment. The Dutch government explains that CE marking is used only when it’s required for the product group and the product meets the applicable requirements. A CE mark on its own says nothing about a UPS’s runtime or whether it’s suitable for a damp location.