Papermaker with a demonstration stand
Wants to show the structure of intact paper on the spot and needs a stable set-up with an image visitors can follow.
For a demonstration using intact paper, choose a stable surface-viewing model with adjustable lighting. Choose a computer-connected model if you also want to display or capture images, or a model with a built-in screen if visitors need to view them without a computer. High digital magnification alone is not enough to identify fibre types: the American Institute for Conservation generally describes this as requiring examination of a sample. Check the power supply, storage, software and applicable product requirements for the exact model, too.
Wants to show the structure of intact paper on the spot and needs a stable set-up with an image visitors can follow.
Also wants to examine individual fibres and can prepare a sample for comparison with reference material.
Needs an image that can be viewed straight away and must plan for the power supply and screen set-up at the stand.
Choose this option: if you want to view intact sheets in a fixed position and have a computer available for the image and power supply.
Bear in mind: with the Celestron Handheld Digital Microscope Pro, power and display are provided via a computer. The digital magnification shown also depends in part on screen size (Celestron; Microscope World).
Choose this option: if visitors need to view the image directly on the device, without a computer.
Bear in mind: check which power supply the exact set-up requires before the fair.
Choose this option: if you want to view prepared fibre samples as well as intact paper.
Bear in mind: according to Bresser, viewing images digitally through the Bresser Biolux NV examined here requires a computer running Windows software.
| What to consider | What to look for | Which consumers is this important for? |
|---|---|---|
| Stable image of intact paper | Check the adjustable stand, focusing and adjustable top lighting. | I want to show intact sheets steadily at a fair and adjust the lighting so visitors can view the details. Around 40% of consumers prioritise a stable demonstration of the paper surface. |
| Examining fibres properly | Check that transmitted light and use with prepared samples are suitable for the examination you want to carry out. | If I want to examine fibres properly, I need to know whether I can prepare a sample and whether the approach is suitable for my specimen. Around 30% of consumers prioritise examining individual fibres. |
| Displaying images without a computer | Check whether the device has its own screen and what power supply the stand set-up requires. | Without a computer at the stand, I want visitors to see the image straight away on the device, and I want to arrange the power supply in advance. Around 20% of consumers prioritise viewing images directly without a computer. |
| Capturing and comparing images | Check the storage options and whether the software is compatible with your computer. | I want to save images of different samples and compare them side by side, so I check that the storage and software suit my set-up. Around 10% of consumers prioritise capturing and comparing images. |
A high digital magnification figure does not, by itself, prove that fibres can be identified. With digital microscopes, the magnification shown also depends in part on screen size. The American Institute for Conservation describes fibre identification as requiring examination of a sample and its fibre morphology.
First decide whether you want to show the surface or examine individual fibres. Then assess the lighting, focusing and suitability for that examination method.
For the Celestron Handheld Digital Microscope Pro examined here, a computer and USB connection are needed for display and power. Without this set-up, visitors will not automatically have an image they can view directly.
If your stand will be without a computer, choose a model with a screen only after checking what power supply it needs.
Viewing an intact sheet is different from removing fibres from the paper. Taking a sample is more invasive and can have consequences when the work is valuable.
For intact paper, start with surface examination. Only take a sample with permission and the appropriate expertise.
The Handheld Digital Microscope Pro 44308 is designed for digital surface inspection using a computer.
The 7-inch-screen model examined here is an option for displaying images directly during a demonstration.
The camera-equipped Biolux NV is designed for anyone who wants to view transmitted-light samples as well as surface images.
The zPix 300 MM-940 is a digital USB microscope that you can compare with a set-up using a stand.
You can view the surface, but that does not automatically identify the fibres. The American Institute for Conservation generally describes this as requiring examination of a sample and its fibre morphology, with interpretation and reference material for comparison.
Place an intact sheet securely beneath a surface-viewing model, then adjust the focus and lighting. Removing fibres is a separate, more invasive step; do not do this to valuable paper without permission.
Check whether the model you choose needs a computer, a suitable power supply or storage media, and whether its software works with your computer. If there is a problem with a consumer purchase, contact the seller. The Dutch government explains that the Netherlands has no fixed statutory guarantee period.
Electrical or electronic equipment placed on the market in the Netherlands must meet the applicable European product requirements. For equipment covered by CE rules, Business.gov.nl, the Dutch government's business information portal, explains CE marking and the EU declaration of conformity. For many online purchases made by consumers from a business, a 14-day cooling-off period generally applies. The Dutch government notes that this does not necessarily apply, for example, to a purchase from a private individual.